2026-02 O-RAN F2F Rome - Lobby Demo

2026-02 O-RAN F2F Rome - Lobby Demo

Feb 2, 2026
Collaborative Demo at O-RAN Alliance - F2F - February 2026 - Rome
Open-Source Demo: O-RAN UCTG Network Energy Saving Use Case
See Video (youtube), Video (SD) for more information

Scope

Several teams are currently working on a demo in the networking-area/lobby at the O-RAN F2F in Rome first week of February 2026 in the context of O-RAN OSFG. The guiding use case was defined by O-RAN MVP-C and is called "Energy Saving" (link to spec see Option 1 - NonRtRic, rApp based, O1 based)

The teams in random order are (please update and/or correct)

This page is used to share content and align the efforts across the teams, projects and organisations.

Description

Please see the target description of the use case in related O-RAN documents: O-RAN Network Energy Saving Use Cases Technical Report 2.0 (6.2.1 Option 1: Non-RT RIC Deployment - rApp-based, O1-based).

For the demonstration within the lobby/networking of 2026-02 O-RAN Alliance f2f meeting in Rome, several simplification are needed to meet the time lines and to reuse existing implementations. Such simplifications are documented in this page and are subject of future implementations and demonstrations.

Flow Diagrams

We distinglish bweteern the flow diagreams of the target and the current implementaion for the 2026-02 O-RAN f2f meeting in Rome.

Long term Target

The following diagram is inherit from the O-RAN network energy saving use case option 1 description (Non-Rt-Ric deployment, rApp-based, O1 based) and serves as the target to guide implementations and discussions.

image-20260112-103626.png

Source: https://lf-o-ran-sc.atlassian.net/wiki/download/attachments/726925405/target-use-case-energy-saving-o1-based.puml?api=v2

Simplification for 2026-02 O-RAN F2F in Rome

logic: UE loss detection in O-DU-NrCellDU triggers rApp to disable energy saving on O-RU.

image-20260113-155042.png

Source: https://lf-o-ran-sc.atlassian.net/wiki/download/attachments/726925405/2026-02-use-case-energy-saving-o1-based.puml?api=v2

Components

text

Simplifications

text

Status

text

Presentation of Communication to Commercial O-RU in ODLUX

Jan 9, 2026 

@Alex Stancu connected the Commercial O-RU to a SMO OAM deployment in COSMOS at 10.160.2.58.
Question: @Ivan Seskar@Alex Stancu Do we need to use another server for SMO NonRt-RIC and LFN Duranta integration?

 

Trigger at ODLUX to perform a manual configuration. The trigger should come via an rApp at the Demo.

image-20260110-133057.png

The configuration is reflected at o-ran-hardware:power-state.

image-20260110-133020.png
image-20260110-133143.png

 

Summary: : Setting the “energy-savings” to “trAVision ue”, then the operational state goes to “sleeping”; setting the “energy-savings” to “false”, operational state goes to “awake”

Question: @Ivan Seskar@Alex Stancu Is the change reflected in a Grafana Dashboard?

Logistics

Vision of a the catering area

Left screen shows the Energy Saving Dashboard,

Right screen shows the videos in a loop, presentations, terminals, ….

image-20260113-131009.png

 

 

References